Pump
In the Pump controller screen, you will be able to observe: The output of the pump controller when not in use and performing a hydraulic function.
The description tells you the function associated with the parameter Note the four traction controllers that could be fitted to your truck follow the same general parameter layout to the pump controller with slight differences in names and purposes
Mast Sensor β If the voltage is high then the mast is in use
Steer Sensor β If the voltage is high then the trucks wheel(s) are turning via a mode change or steering wheel
Analog 9 β If the voltage is high then analog 9 is turned ON
Override Sw β If the circle is green the override switch is turned ON
Seat Sw β If the circle is green then the seat switch is turned ON
Seatbelt Sw β If the circle is green then the seatbelt switch is turned ON
Mast Sw2 β If the circle is green then mast switch 2 is turned ON
Mast Sw3 β If the circle is green then mast switch 3 is turned ON
Sw12 β If circle is green then switch 12 is on
Sw13 β If circle is green then switch 13 is on
Warning Light FWD β Either ON = 100% or OFF = 0%, if ON the warning light is turned ON while driving forward
Universal Ouptut1 β Either ON = 100% or OFF = 0%, if ON then the universal output 1 is turned ON
Universal Ouptut2 β Either ON = 100% or OFF = 0%, if ON then the universal output 2 is turned ON
Warning Light REV β Either ON = 100% or OFF = 0%, if ON the warning light is turned ON while reversing
Main Contactor β If the percentage is low then the main contactor is open
Cooling Fan 1 β Either ON = 100% or OFF = 0%, if ON cooling fan is turned ON
Lock Valves β Either ON = 100% or OFF = 0%, if ON hydraulic valves are locked
Interlock β If the circle is green then the interlock is turned ON
ThrottleCommand β How much throttle input the pump controller is receiving
BrakeCommand β How much brake input the pump controller is receiving
Regen β If the circle is green then the brake regen is ON
ControllerCurrent β The amount of current the pump controller currently has
MotorRPM β The RPM of the pump motor
MotorTemperature β The temperature of the pump motor
Current5V β Number of volts that flows through pump controller
SupplyCurrent12V β The supplied power the controller requires to power ON