DAP Mast / Reach Point 1 / 2 / 3 / 4
In the DAP Mast/Reach point screens, you will be able to change parameters relating to the trucks DAP Mast/Reach Points.
Each DAP is an input to control the speeds/lift speed/reach speed of the truck
Active Mode – If ON, DAP point is enabled
Active High – If ON, input logic is high to activate, else if OFF, input logic is low to activate
Position – Used with height feedback, so DAP can reach exact height/distance.
Override Enable – Allows the DAP to be overridden
Override Speed – Percentage of max drive speed truck can go when DAP is being overridden
Truck Speed – Percentage of max speed truck can go when DAP is active
Lift Speed dir A – Percentage of current max lift speed mast can go when DAP is active
Lift Speed dir B – Percentage of current max lower speed mast can go when DAP is active
Carriage Speed dir A – Percentage of current max reach out speed mast can go when DAP is active
Carriage Speed dir B – Percentage of current max reach in speed mast can go when DAP is active